Gas Turbines | Gas Power Energy Storage Solar Wind USA

Gas Turbine Power Plant LPG Hydrogen Fuel MW
20190826_170447.jpg
20190827_140747.jpg
20190827_142803.jpg
20190827_141118.jpg
20190827_142102.jpg

Secure Supplies Gas Turbines New and Used from Man Kawasaki and Others . KW and MW Class

Current Stock includes 

  • 7 MW Kawasaki  Units  Dual Fuel: Natural Gas, Landfill Gas 3 Phase /Both 60 hz or 50 hz/4160 V

  • 12 MW MAN Units Dual Fuel: Natural Gas, Landfill Gas 3 Phase /Both 60 hz or 50 hz/4160 V

  • 32 MW Kawasaki Units Dual Fuel: Natural Gas, Landfill Gas 3 Phase /Both 60 hz or 50 hz/11  KV

​​

danieldonatelli1@gmail.com 

Mb + 1 520 848 1650 

EXTRA DETAILS CURRENT STOCK 

=================================================

7  MW   Kawasaki   turbines N°6  pcs:  all  this  turbines  are  bifuel  mean :    liquid/gas    60  HZ 

                                                                         VERY GREAT CONDITION NEW AND BEST DEAL FOR PRICE>

( i have adapter to make 50 kz or 60 hz as required etc for all items)

6 x 7 mw Kawasaki  4 new 2 4000 hrs price 3 million each 

================================================= 

12 Mw   MAN   turbines  N°3  Pcs  total  36  Mw  :  bifuel  liquid/gas  6600  volts  50 HZ  NEW UNITS

3 x 12 mw  MAN NEW  

Price indication is  USD  5.8 million each 

 12 mw  each usd CIF  Africa Ports  3 PC ONLY 

=================================================

34 Mw  1 only  HITACHI  11.500 volt  50  HZ  :  GAS                       AMAZING UNIT 

34 MW unit  700 hrs 

Price USD $16,800,000

=================================================

Maker        Model                 Engine               Unit    Vintage    Out put  Voltage  Hz    Fuel    Hour      Price (US$)    
Kholer         2000REOZM    Mitsubishi S16R     2    2011      2000KVA    400V    50    H/Oil                        800k
Wartsila      18V34SG          Gas Engine            1    2005       6000KW    6600V  50   Gas                          $2
.4 mil
Mitsubishi    S16R-PTA        Diesel Engine        1    2014      1000Kw    6600V    50    H/Oil    628              468k
Mitsubishi    S17R-PTA        Diesel Engine        1    2014      1000Kw    6600V    50    H/Oil    33                 680k
KHI              PU-5000   M1T-26 Gas Turbine     3    2018      5000KW    6600V    50    Gas    Never Used  $2.6 mil  
Siemens      Typhoon  TCP-5001 Gas Turbine   1    2004     5070KW    3300V    50    Gas    100,000        $2.4 mil
Mitsubishi    18KU30GA      Gas Engine             1    2004     5750KW    3450V    50    Gas                         $2.1 mil  
                                                    
PRICE: CIF ex JAPAN

10% Down Payment,

90% wire transfer prior to shipment                                            
                                       
RS: Ready to Ship    Call Message Daniel Whatsapp + 1 520 848 1659  danieldonatelli1@gmail.com

Thermal efficiency and fuel consumption rate listed in specification. 

The operational cost estimate is per kw aprox $5 per kw annually for service refit can be 

 high aprox 10 per kw but not need for 10 years . Refit $20/kw ​

1.KHI 6.6MW x 6 units with Steam Turbine generator

   Fuel: Natural Gas (no diesel oil)

   Fuel Consumption : 2,126Nm3/hour under conditions of Fuel Calorific Value 41.609MJ/Nm3 , 0°C 

   atmosphere temperature,   90% water injection rate

 

2. RR/ABB Diesel Engine/Generator ENGINES 6MW x 2 units

   Please refer to RR's technical data there is statement of Fuel Oil Data:

   Specific Oil Consumption 183g/kWh    Fuel Consumption at MCR 1275L/H  the H2 Supplementation system by Secure Supplies can fit these  perfectly. with auto feeder . 

 

3. 34MW Mitsubishi-HItachi Power System Gas Turbine, Siemens Generator

   Fuel is natural gas.    Fuel consumption; unable to check firmly but it is a scale so times the 7 mw  numbers by 5 now but will check documents after receipt of the LOI, however this unit may be gone this week unless otherwise we receive the deposit.

Please remember these model in particular are the most efficient  made and are current state of the art from Japan.

12 mw aprox 3900 Nm3/hour under same calorific value as 7 mw

O & M  is between  80,000 and 140,000 per year for the turbines

This is double a engine , but the efficiency is 90%  a engine is 39% so it is more than made back 

in the power made and fuel cost saving for the power volume in mw class  as you would need 7 engine to do same loading job

2020 Slide System Power Gen Component Co
Gas Turbine Power Plant LPG Hydrogen Fuel MW

Secure Supplies Brings together companies with well over has over 60 years of experience in providing clients with exceptional power equipment.

 

We stock a selective yet comprehensive range of gas turbine generators ranging from

200 KW up to 100 MW.

 

Manufacturers

We choose only to stock only the world’s most reputable manufacturers. This allows us to ensure our clients get the power they need, when they need it. Some of the product lines we carry include: 

  • ·Kawasaki 

  •  MAN

  •  GE

  • ·Solar Turbines Inc

  • ·Siemens Westinghouse

  • ·Rolls Royce

  • ·Pratt & Whitney

We independently review each manufacturer we work with on numerous variables to ensure we only supply the highest quality products on the market. Our clients know that when they work with Secure Supplies , they will be getting quality products, supplied by experienced and engineer-driven experts. 

Fully Assembled  

If you go through the manufacturing process, assembly time can range from months to years. (presuming everything goes to plan).  Secure Supplies Energy understands that “Time is Money.”

Our equipment is ready to ship and start up at your command. 

When you work with Secure Supplies  the complex and lengthy manufacturing process is all done for you. All gas turbines we supply are provided to our clients ready to start up from the moment following installation.

As you would rightly expect, all our products are pre-assembled with standard components, related auxiliaries, controls, and switchgear. Why run the risk of potentially missing deadlines due to delayed or incorrect assembly? Work with Secure Supplies Energy and get fully refurbished equipment on site in a matter of days.

 

Quality Control

Occasionally generators do not work as expected when you on initial start up.

 

This can be due to a manufacturing error or inexperience during assembly. We understand how important it is to have products work as expected from day one of operation. It’s no secret that an improperly functioning turbine or generator can severely delay a project, potentially putting it behind schedule to meet a deadline.

 

Secure Supplies Energy  utilizes our own in house quality control methodology, formulated from industry standard best practices, and our decades of first-hand experience. We verify each and every gas turbine that we provide, ensuring it will work as intended as soon as it reaches your hands. When combined, our assembly and quality control procedures greatly minimize the risk of unexpected delays during assembly or initial operation.

FUEL SAVINGS
So you Profit from POWER Production

MW Class Turbine Startup Cost 
A 13,750-hp (10.26-kw) gas turbine uses approximately 3000 lb (1360 kg) 
of pipeline gas in the expander each start, which is approximately  62 million Btu (65.41 GJ) each start. 
With a gas value of $2.00 per million Btu ($1.89/GJ) LHV, this is $124 per start.

 

Engine Starter
A diesel / H2 engine starter for the same gas turbine would use approximately 14 lb (6.35 kg)
of diesel fuel, or approximately 0.25 million Btu (263.7 GJ). At $15 per barrel, or $2.68 per
million Btu ($2.54/GJ), one start would cost only $.67.

 

Start and Idle
Start And Idle 16 mins prior load being applied Fuel used in the gas turbine combustion
system up to the point of minimum load shaft governing speed is relatively insignificant. A
13,750-hp (10.26-kw) industrial gas turbine would consume only 0.6 million Btu (0.654 MJ). But
how much fuel is used during idling time before the operator actually loads the gas turbine?
Rough estimates show a 13,750-hp (10.26-kw) turbine would use approximately 25 million Btu/
hr (26.37 GJ/hr). If the turbine were started 20 times per year, and it were allowed to idle
an average of 15 min, each start, and fuel costs $2.00 per million Btu ($1.89/GJ), then one might
consider that wasted energy for idling during the year a. ated to $250/year. Once again, we
see that starting fuel is not a subject forsignificant fuel-consumption reduction.

 

Gas Turbine Fuel Consumption

 
Secure Supplies Has Several Chp and Intake Cooling Systems which can add 10 to 20%  more Efficiency.
the inlet air dry bulb temperature is usually kept 5 F (3 C) or more above wet bulb temperature. If an ambient air dry bulb temperature of 80 F (27 C) and 30 percent relative humidity is assumed, reference to a psychrometric chart shows that the turbine inlet air dry bulb temperature could be safely reduced
to 6 5 F (18 C) with evaporative cooling.


As shown in Fig. 2, the industrial gas turbine full load heat rate at 8o F (27 C) might be 7650 Btu/hphr (10.82 GJ/kwhr), but at 65 F (18 C), the full load heat rate is 7470 Btu/hphr 10.56 GJ/kwhr), or approximately 2.4 percent better. For rough estimating purposes, assume that the ambient temperature was 80 F (27 C) for 3000 hr per year and the relative humidity was 30 percent for the same period. Further assume that during this period, the gas turbine was operating at its full-load capability of 13,337
hp (9949 kw). By using the evaporative cooler for this period, and assuming a fuel cost of
$2.00 per million Btu ($1.89/GJ), the annual fuel savings would be approximately $14,400/year. It
must be understood that even for these exact conditions, this is an approximation 
When the evaporative cooler is operating and the gas turbine could, therefore, produce more power than 13,337
hp, the fuel rates given by Fig. 2 must be adjusted slightly (possibly an improvement as will
be discussed later .


Again, by use of a psychrometric chart and gas turbine air flow data, and for the aforementioned assumed conditions, the evaporative cooler water consumption is calculated to be 2.78 gal (10,52 1) of water per minute. If the annual cost of this water supply is $2.00 per thousand gallons ($0.52 per thousand liters), then the annual water costs are $1000 per year. The net savings would then be $13,400/year. If the
installed cost of the evaporative cooler were $50,000, the gross payout would be 3.73 years.
In addition, credit could be taken for the additional available power.

 

EGR OPTIMUM REGENERATIVE EFFECTIVENESS


In searching for ways to reduce fuel consumption, the question often arises as to whether more energy can be recovered from the exhaust of a gas turbine. For many years, a heat exchanger called a regenerator has been used with industrial gas turbines for this purpose. As shown in Fig. 3, the regenerator captures heat from the gas turbine exhaust and transfers this heat to the compressed air entering the combustion chamber. Regenerator effectiveness is a measure of how much gas turbine exhaust heat is recovered. For many years, regenerators with an effectiveness of approximately 81 percent have been used with gas turbines. To increase the effectiveness and thereby use more of the
exhaust heat, more heat exchange surface must be built into the regenerator.

an estimate of how gas turbin efficiency and regenerator cost varies with regenerator effectiveness. Note that when effectiveness is increased from 81 to 85 percent, the regenerator heat exchanging surface must increase by approximately 50 percent, and this additional regenerator surface costs approximately $150,000.


Using this data, and assuming a 13,750-hp (10.26-kw) gas turbine operating at full load at
ISO conditions for 8500 hr/year, Fig. 5 demonstrates the  optimum regenerator effectiveness
for different fuel costs.

 

Gas Turbine Fuel Consumption
Gas Turbine Power Plant LPG Hydrogen Fuel MW

Tailored To The Project

We provide generators that run on all common fuel types, including: 

  • Factory By pass Gas Streams 

  • Natural Gas

  • ·Hydrogen

  •  Landfill Gas

  •  Water Fuels

  • ·#2 Oil a variety of purity and mixtures can be used. Including Oil and Gas together.

  • Bio Gas

  • Bio Diesel

  • Diesel

Gas turbines supplied by Secure Supplies Energy are highly versatile in terms of potential applications. We provide several customization options on most of the gas generators we supply – enabling you to tailor your generator to your business application. 

HRSG the MODERN CHP  Using Refrigerant Gas COP 90% is a Achievable.

We can fit highly efficient Heat Recovery Steam Generators (HRSG) to most of our generators during assembly. By capturing the exhaust energy that would otherwise be expelled into the atmosphere, an HRSG systems will reuse the heat to power steam turbines and generate more efficient electricity. The result of which is cleaner, greener, and cheaper energy.

 

Mobile Modular Design

Often a generator will need to be moved several times during its long lifespan. We can provide containerized generators in a wide range of sizes and power outputs. Our secure and hardy metal casings will allow you to access truly mobile energy, wherever and whenever it is required. The secure trailer mounted design allows for easy highway and jobsite access.

 

Why Lean Gas Fuels Such as Hydrogen ,Bio Gas ,  Ammonia or Natural Gas?

Jet Engines and Gas Turbines are Dsigned for Lean Gas fuel infact they love fast burn rates or fast laminar flames speeds from fuels such as pure Hydrogen.

 

Gas turbines are the cleanest and greenest non-renewable generators money can buy

 

They are outperforming diesel generators in terms of cleanliness and quietness. Gas is one of the most economic energy choices on the market (second only to coal and much cleaner). Getting clean cheap energy has never been easier.

 

Call Secure Supplies Energy  today and speak with one of our highly-trained representatives to discuss how we can supply you with gas turbine generator in just a matter of days.

Daniel Donatelli 

Mb + 1 520 848 1659 

danieldonatelli1@gmail.com 

Gas Turbine Power Plant LPG Hydrogen Fuel MW
Gas Turbine Power Plant LPG Hydrogen Fuel MW
Gas Turbine Power Plant LPG Hydrogen Fuel MW
Gas Turbine Power Plant LPG Hydrogen Fuel MW
Gas Turbine Power Plant LPG Hydrogen Fuel MW
Gas Turbine Power Plant LPG Hydrogen Fuel MW
Gas Turbine Power Plant LPG Hydrogen Fuel MW
Gas Turbine Power Plant LPG Hydrogen Fuel MW
Gas Turbine Power Plant LPG Hydrogen Fuel MW